Home ProductsWater Purifying Chemicals

Active Sludge Treatment Bacteria Microorganism Aerobic Tank Biological Agent

Certification
China Yixing bluwat chemicals co.,ltd certification
China Yixing bluwat chemicals co.,ltd certification
Customer Reviews
We are buying Bluwat BWD-01 Water Decoloring Agent and Polyelectrolyte, both has very good performance in Bangladesh textile plants effluent treatment

—— Afroz Noman

Under here with, we would like to confirm that BWD-01 water decoloring agent and PAC supplierd from BLUWAT had good perfromance.

—— Momhamed Shajahan

Hereby, we confirm that Blufloc Polyacryalmide had very good performance in our ETP for water treatment and sludge dewatering, we will have more order

—— Amin Binns

Under here with, we'd like to certified that BWD-01 water decoloring agent of 200tons suppplied in 2015, works so well.

—— Frank Stuart

I'm Online Chat Now

Active Sludge Treatment Bacteria Microorganism Aerobic Tank Biological Agent

Active Sludge Treatment Bacteria Microorganism Aerobic Tank Biological Agent
Active Sludge Treatment Bacteria Microorganism Aerobic Tank Biological Agent Active Sludge Treatment Bacteria Microorganism Aerobic Tank Biological Agent

Large Image :  Active Sludge Treatment Bacteria Microorganism Aerobic Tank Biological Agent

Product Details:
Place of Origin: China
Brand Name: Bluwat
Certification: ISO9001
Model Number: BWG
Payment & Shipping Terms:
Minimum Order Quantity: 1000KG
Packaging Details: 25kg bag
Delivery Time: 15 days
Payment Terms: L/C,T/T, Western Union

Active Sludge Treatment Bacteria Microorganism Aerobic Tank Biological Agent

Description
Appearance: Black Powder Application: Industrial Wastewater
Using Conditions: Activated Sludge Process Material: Bacteria Compound
Dosage: 0.01%
High Light:

Active Sludge Treatment Agent

,

BWG Bio Cleaning Agent

,

Microorganism Aerobic Tank Biological Agent

Active Sludge Treatment Bacteria Microorganism Aerobic Tank Biological Treatment Agent

 

Product Description

  • BWG is a special product developed according to the unique characteristics of the organism when it grows. It has special high efficiency for various types of industrial wastewater, especially for textile wastewater, we got very good treatment results.
  • BWG can be used as biological strengthening technology in the biological aeration tank, to ensure that the treated water to be discharged at higher standard or be reused at higher quality. Solve the problem of biological treatment in short time and get better removal of COD, BOD, NH3-N and TN.

The Advantages Of BWG Bio-Cleaning Agent

1

There are a lot of organism carriers in a biological system, it can increase biological tank treatment capacity, greatly improve the shock resistance of the biological system;

2

Solve sludge bulking problem that easily occurs in the biological tank;

3

Increase the COD removal rate to 90% in the biological system, remove 50% of TN, NH3-N can drop to almost Zero;

4

Withstand 4% high salinity environment;

5

Suitable for all kinds of wastewater, especially for difficult chemical industrial wastewater;

6

When WWTP has the breakdown of the biological system because of shock loading or other reasons, BWG can be used as a stabilizer to restructure biological system and ensure the stable operation of the system in short time (in one week).

7

Depending on our application cases’ data from leather wastewater, printing & dyeing wastewater, chemical wastewater, show that when the biological system is running stable, it can reduce usage of other coagulants with WWTP or stop using coagulants, reduce the generation of sludge, and greatly reduce the comprehensive cost

 

What is the application method?

1 BWG is added in aerobic biological tank directly.
2 1st day use BWG, the dosage is 0.1% of daily wastewater volume, for example, when daily wastewater treatment volume is 4000m3, the first time to add BWG is 4 tons(if biological water stay time is more than 12 hours, dosage is 0.1% of biological tank volume/m3);
3 After 1st day dosage, every day dosage of BWG is 0.01% of wastewater volume, such as the daily treatment of 4000 m3 of wastewater, the daily dosage is 400 kg
4 If used in chemical industrial wastewater, because the chemical wastewater organic matter is very single situation, need to add extra nutritional sources, such as glucose, flour and other easily degradable organic compounds as carbon resource;
5 biological conditions must be conducted under the normal biological conditions, such as: PH value to be maintained in the range of 6 to 9, the inlet water temperature not over 47°C, solution oxygen to be maintained in 2 to 5mg/l, sludge concentration to be controlled in around 5000mg/l, SV30 to be controlled over 30%.

 

 

Successful Case in Textile Factory ETP:

 

Raw water conditions:

Water Amount PH Color COD Ammonia nitrogen Water Temperature
2000t/d ≈7 Dark Purple Red 1000mg/l 12 mg/l 30~35℃
 
 
Water from outlet of Aerobic tank:
Water Amount PH Color COD Ammonia nitrogen Water Temperature
2000t/d ≈7.2 Light red 380mg/l 8.2 mg/l 30~35℃
 
 
After using BWG Bio-cleaning Agent in Aerobic tank, after 15 days 
Water Amount PH Color COD Ammonia nitrogen Water Temperature
2000t/d ≈7.3 Very slight redish 110mg/l 2.7 mg/l 30~35℃
 
 
Active Sludge Treatment Bacteria Microorganism Aerobic Tank Biological Agent 0

Contact Details
Yixing bluwat chemicals co.,ltd

Contact Person: Mr. Eric Min

Tel: +8613861499902

Send your inquiry directly to us (0 / 3000)