| Brand Name: | Bluwat |
| Model Number: | C9070 |
| MOQ: | 1 Ton |
| Price: | negotiable |
| Delivery Time: | 5-8 Working Days |
| Payment Terms: | L/C,D/A,D/P,T/T |
60-70% cationic charge within the Very High molecular-weight class
Blufloc C9070 is a cationic polyacrylamide (CPAM) polymer flocculant supplied as off-white granular powder with at least 89% solids. The TDS lists a 60-70% cationic charge range for evaluating clarification, sludge thickening and dewatering. Also described as a cationic polyelectrolyte, it is selected by testing the actual feed and separation task.
Cationic polyacrylamide sold as Blufloc C9070, with a Very High molecular-weight classification in the property table.
Cationic charge degree: Very High (60-70%). Compare this specification with the actual application response.
Off-white granular powder, 20-100 mesh, with 89% minimum solid content. Packaging is selected from the options listed for this grade.
| Property | Grade-specific TDS value |
|---|---|
| Product grade | Blufloc C9070 |
| Appearance | Free-flowing Off-White Granular Powder |
| Ionic Charge | Cationic |
| Particle Size | 20-100 Mesh |
| Molecular weight (TDS classification) | Very High |
| Cationic charge degree | Very High (60-70%) |
| Solid Content | 89% Min. |
| Bulk density (unit not stated in TDS) | About 0.8 |
| Specific Gravity at 25°C | 1.01-1.1 |
| Recommended Working Concentration | 0.2-0.5% |
| pH (1% aqueous solution) | 3-6 |
| Storage temperature (°C) | 0 - 35 |
| Shelf Life | 2 years |
Molecular weight is given as a TDS classification, without a numerical range. Bulk-density units are not specified in the supplied document. The specific-gravity entry gives 25°C but no sample concentration. The pH value refers to the stated test solution, not a treatment-pH operating window.
The application list includes raw-water and industrial clarification, industrial or sewage-sludge thickening and dewatering, paper retention, sugar mud settling, and mining or metallurgy water recovery and sludge treatment. The TDS also mentions centrifugal filters. Use the actual feed and equipment when evaluating whether C9070 meets the intended liquid-quality and solids-handling targets.
The supplied TDS lists raw-water flocculation and clarification, industrial primary clarification, and secondary or tertiary treatment. Evaluate the grade at the intended process stage with representative feed and the existing treatment chemicals.
Industrial and sewage treatment include sludge thickening and dewatering. Define the liquid-quality and solids-handling targets for the actual equipment. A settling observation alone does not establish a final dewatered-cake result.
Paper retention, sugar-manufacturing mud settling, and mining or metallurgy water recovery and sludge treatment are listed. Qualify each application separately and confirm any specific end-use documentation with Bluwat.
Centrifugal filters are mentioned in the TDS; evaluate the grade and dose using representative equipment conditions.
C9070 lists 60-70% charge and a Very High molecular-weight class. C8070 lists 65-70% and High, while C9080 lists 75-80% and Very High. These are specification differences for a laboratory comparison, not a universal performance order.
| Grade | Molecular-weight class | TDS charge entry | Working concentration |
|---|---|---|---|
| C9070 | Very High | Very High (60-70%) | 0.2-0.5% |
| C8070 | High | Very High (65-70%) | 0.2-0.5% |
| C9080 | Very High | Very High (75-80%) | 0.1-0.5% |
This comparison describes TDS specification differences. Select grade and dose using the actual feed and equipment results.
The TDS recommends a 0.2-0.5% solution before use. This is the prepared polymer-solution concentration, not a fixed dose in the treatment stream.
The supplied instructions specify plastic, enamel or fiberglass containers for solution storage and advise against metal containers. Request the appropriate dissolution and mixing procedure for the actual water and equipment; no fixed mixing speed or dissolution time is provided.
Compare doses on the actual water, sludge, slurry or formulation. Record the product grade, solution concentration, dose basis, feed condition and separation observations. The TDS requires dose selection from laboratory results.
Include the existing coagulant or process-aid program in the evaluation. Confirm liquid quality and solids handling under equipment conditions before routine dosing; the TDS does not define one chemical-addition sequence for every application.
Packaging listed for Blufloc C9070: 25 kg net polybags, 25 kg net Kraft paper bags, or 750 kg big bags. Confirm the selected pack, required quantity and destination with the quotation.
Store in the original packaging in a cool, dry place away from heat, flame and direct sunlight. The listed storage temperature is 0-35°C. The TDS states a two-year shelf life. Follow the current product label and SDS for handling instructions.
Yixing Bluwat Chemicals Co., Ltd. is a manufacturer and exporter of water treatment chemicals based in Yixing, Jiangsu, China. Our business began in 2000, the company was formally established in 2002, and our Yixing plant began production in 2004.
Bluwat operates three production bases and supplies customers in around 100 countries and regions. Our portfolio includes Blufloc polyacrylamide powders and emulsions, Water Decoloring Agent, PolyDADMAC, Polyamine, PAC, ACH, ferric sulphate and specialty treatment chemicals.
Our team supports product selection around the actual water, sludge or process stream. For a purchasing review, request the current grade-specific TDS, SDS and batch quality documents, and discuss sample evaluation, packaging and export requirements with Bluwat.
Share your treatment objective, feed information and existing chemical program so that the discussion addresses the intended use of C9070. Manufacturing supply, grade documentation and application evaluation should be reviewed together when preparing the order.
The supplied property table lists Very High charge at 60-70%, with Very High molecular weight. Confirm the current grade-specific document with the quotation.
C9070 lists 60-70% charge and Very High molecular weight. C8070 lists 65-70% and High. Use the full grade code and exact specification in the trial record.
Related product names include Cationic Polyacrylamide, Cationic PAM, CPAM, Cationic Polyelectrolyte and Polymer Flocculant. Keep C9070 with the name when enquiring, because a general PAM name does not identify a specific grade.
Establish the dose by laboratory trials and confirmation in the intended equipment. The working-concentration entry 0.2-0.5% describes the prepared solution; it is not a treatment dose in mg/L.
Compare it with the existing product on the same feed and dose basis. The TDS does not establish automatic equivalence to another grade or unconditional replacement of a coagulant program.
Contact Bluwat with the full grade code, application, feed information, required quantity, packaging and destination. Request current grade-specific technical and quality documents and discuss sample evaluation for the intended duty.
Tell Bluwat the grade, application, required quantity and packaging. Discuss representative sample testing and request the current product specification before final selection.