Description:
Blufloc Polyacrylamide in Sugar Industry:
Trade Name: | Anionic / Flocculant / Polyelectrolyte / APAM |
Active Ingredient: | High molecular weight polymer |
Chemical Name: | Anionic Polyacrylamide / Polyelectrolyte / Flocculant / |
CAS No.: | 9003-05-8 |
Standard: | GB17514-2008 |
Brand: | Blufloc |
Equivalent to: | LT25, LT25, Chemfloc LT27, 605 etc |
Certification: | ISO, SGS |
MOQ: | 500kgs |
Port of Loading: | Shanghai Port, China |
Delivery Time: | Within 10 Working Days After Got Your Payment |
Package: | Packed in 25kgs kraft bag or white PE bag on pallet and 18-20ton/FCL, or 750kgs big bag |
Applications: | Sugar clarification, sedimentation and flotation |
Sample: | Free to test |
Blufloc AS5615 Polyacrylamide Specifications: | |
Appearance: | Off-White Granular Powder |
Ionic Charge: | Anionic |
Molecular Weight: | Medium high |
Hydrolysis Degree: | Medium low |
Bulk Density: | About 0.6-0.8 |
Solid Content: | 89%min |
Residual Monomer: | <0.05% |
Active Content: | 100% |
Specific Gravity at 25°C: | 1.01-1.1 |
Recommended Working Concentration: | 0.1-0.5% |
PH (1% aqua solution): | 6-9 |
Melt Raw Sugar Flotation:
Blufloc AS5615 Grade Competitive Advantage:
1 | Medium Molecular Weight and high Charge Degree. |
2 | Economical to use - lower dosage levels. |
3 | For Water treatment as flocculant to make flocs |
4 | Easily soluble in water; dissolves rapidly. |
5 | Non corrosive of suggested dosage, economical and effective at low levels. |
6 | 10 years manufacturing experience, with more than 20 technical engineers |
Blufloc AS5615 Grade Application Methods:
1 | Dissolving | Polyacrylamdie (polyelectrolyte/flocculant) should be standardly be dissolved to 0.1-0.5% concentration. |
2 | Dissolving | The time required to dissolve the flocculant varies according to the type of flocculant, water quality, temperature and agitation. However, most flocculants generally require around 1 hour of agitation to completely dissolve the powder. Incomplete mixture of flocculant or lumping may inhibit the performance of the flocculant. |
3 | Agitation | The ideal revolution of the agitator is between 200-400rpm. A high speed agitator operating without reducing the revolution of a motor is not advised, since it may cut the molecules of the flocculant. An ideal agitator motor should be of 1HP for a 1-2m3 mixing tank. |
4 | Application | The dosage range of varies from 1 - 3.0 ppm depending upon the type of effluent and application. Advised to do jar tests for evaluating the functioning and approximate dosage. |
5 | Jar Test: | Put sample of effluent in a beaker and add it as designated, agitate for 1 minute at 100-120 rpm and then slowly agitate at 60rpm. Determine the flocs properly at this time and note the sedimentation and clarity of top solution. |
Blufloc AS5615 Grade Package and Storage: