| Brand Name: | BLUWAT |
| Model Number: | Blufloc PAC Series |
| MOQ: | 5 tons |
| Price: | negotiable |
| Delivery Time: | Within 15 workdays recdive the payment or L/C |
| Payment Terms: | L/C, T/T, D/P,, D/A, Western Union |
PAC-01 is a spray-dried white powder polyaluminium chloride developed for drinking water treatment, color-sensitive process water and stable clarification under changing raw-water conditions.
In drinking water treatment, the practical objective is to produce stable clarified water when turbidity and natural organic matter change across the day or season. PAC-01 is used as a coagulant, not as a complete treatment system. Its role is to destabilize colloids and form settleable floc before clarification and filtration.
The grade is positioned for drinking-water and color-sensitive process-water applications, and its spray-dried form dissolves rapidly when the solution is prepared correctly.
The relevant feed is typically screened surface or blended raw water. The main difficulty is that fine clay, silt and negatively charged colloids remain dispersed because electrostatic repulsion prevents natural settling.
As a result, untreated water may show unstable turbidity, weak settling, short filter runs or poor solid-liquid separation. A useful product page must distinguish the removable suspended or colloidal fraction from dissolved contaminants that require other processes.
The recommended role for PAC-01 is to destabilize colloids and form settleable floc before clarification and filtration. It is normally applied after intake screening and raw-water assessment, before flocculation, sedimentation and filtration.
When PAC hydrolyzes in water, positively charged aluminium species reduce particle repulsion. Hydroxide floc then enmeshes fine matter and creates aggregates that can be settled, floated or filtered. Effective rapid mixing must distribute the coagulant before slower floc growth begins.
| Parameter | Specification |
|---|---|
| Product model | PAC-01 |
| Chemical name | Polyaluminium Chloride |
| Appearance | White powder |
| Al2O3 content | 30% min. |
| Basicity | 45–55% |
| Water-insoluble matter | 0.1% max. |
| Drying type | Spray dried |
| Preparation concentration | 2–20% solution before dosing |
| Typical solid-product dosage | About 1–15 g/MT; determine the optimum by jar test |
| Standard packaging | 25kg inner plastic bag with polypropylene woven outer bag |
Relevant use cases include municipal plants, private drinking-water systems and packaged clarification units. Operators should follow raw and settled turbidity, floc size, settling rate, filtered-water turbidity and any locally required residual-aluminium control.
These indicators show whether the treatment target is being achieved and whether the dose is creating unnecessary sludge or downstream carryover.
PAC is a pre-hydrolyzed inorganic polymeric coagulant. After dispersion, its cationic aluminium species adsorb on negatively charged particles and reduce the electrical barrier that keeps them apart. As hydrolysis continues, aluminium hydroxide floc provides a sweep-coagulation surface that captures fine particles.
Separation performance therefore depends on product dose, pH, alkalinity, mixing sequence, flocculation time and the selected settling, DAF or filtration equipment.
Characterize the screened surface or blended raw water, including pH, turbidity or TSS and the contaminants that may remain dissolved.
Prepare the solid PAC as a 2–20% solution with clean water. Allow complete dispersion and keep the solution system clean.
Run a jar test around the TDS reference range of about 1–15 g/MT and reproduce the intended process position: after intake screening and raw-water assessment, before flocculation, sedimentation and filtration.
Use rapid mixing for coagulant distribution, then slower mixing for floc growth. Avoid excessive shear after the floc has formed.
Select the lowest stable dose that meets the target while monitoring raw and settled turbidity, floc size, settling rate, filtered-water turbidity and any locally required residual-aluminium control.
Choose PAC-01 because the white, low-insoluble grade is suitable where treated-water appearance and low residue are important. Start with the product specification, but make the final selection on representative water.
Compare at least three doses, include the current coagulant as a control and keep pH, mixing energy and settling time consistent. The TDS gives about 1–15 g/MT for solid PAC as a general reference; the optimum may differ with the water and must be confirmed by laboratory and plant trials.
PAC-01 and PAC-02 are the starting grades for drinking-water and cleaner process-water duties. PAC-01 is white with 45–55% basicity, while PAC-02 is yellow with 45–85% basicity. PAC-031 is the industrial grade with 29% minimum Al2O3, 50–90% basicity and a higher allowable insoluble fraction. Grade selection should reflect treated-water requirements, feed variability and total treatment cost rather than color alone.
| PAC Grade | Appearance | Al2O3 | Basicity | Typical Positioning |
|---|---|---|---|---|
| PAC-01 | White powder | 30% min. | 45–55% | Drinking water and color-sensitive process water |
| PAC-02 | Yellow powder | Select according to current TDS | 45–85% | Drinking water and cleaner process-water duties |
| PAC-031 | Industrial grade | 29% min. | 50–90% | Industrial water and wastewater treatment |
Bluwat Chemicals has manufactured water-treatment chemicals since 2000. The company operates three production bases, exports to more than 80 countries and has served over 5,000 industrial customers. For drinking water treatment, this experience supports grade matching, sample evaluation and communication between the buyer, sales team and technical team before scale-up.
Direct factory support includes batch COA, current TDS and SDS documents, packing checks and traceable quality control for the selected PAC grade. Buyers can compare PAC-01 with other PAC grades using actual water rather than relying only on product color or one headline parameter.
Solid PAC is packed in a 25kg inner plastic bag with a polypropylene woven outer bag. Store the sealed original package in a cool, dry place away from heat, flame and direct sunlight.
Prepare a 2–20% solution before dosing, using clean water and sufficient mixing. Do not use wet, contaminated or severely caked material without evaluation.
It is a candidate grade because the white, low-insoluble grade is suitable where treated-water appearance and low residue are important. Suitability must still be verified with the actual water, treatment objective and downstream process.
The supplied TDS gives about 1–15 g/MT for solid PAC as a general reference. Start with a dose-response jar test and confirm the result at plant scale; do not copy a dose from another site.
Prepare a 2–20% solution using clean water and adequate mixing. Avoid dumping dry powder directly into a poorly mixed tank, and protect the stored product from moisture.
Track raw and settled turbidity, floc size, settling rate, filtered-water turbidity and any locally required residual-aluminium control. Also verify the limitation that PAC does not replace disinfection, pathogen barriers or compliance monitoring.