logo
Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Polyelectrolyte Flocculant
Created with Pixso. High-Molecular-Weight CPAM Emulsion with Medium to Ultra-High Charge for Chemical Wastewater Sludge Treatment

High-Molecular-Weight CPAM Emulsion with Medium to Ultra-High Charge for Chemical Wastewater Sludge Treatment

Brand Name: BLUWAT
Model Number: Blufloc Emulsion
MOQ: 1000kgs
Price: negotiable
Delivery Time: 5-10days
Detail Information
Place of Origin:
China
Certification:
ISO9001
Product Name:
Cationic Polyacrylamide Emulsion
Abbreviation:
CPAM Emulsion
Product Category:
Water-Soluble Polymer Flocculant
Chemical Type:
Cationic Polyacrylamide Copolymer
Physical Form:
Liquid Emulsion
Appearance:
Milky White Or Off-White Emulsion
Available Formulations:
Oil-Based Emulsion And Water-Based Emulsion
Molecular Weight:
High
Charge Degree:
Medium To Ultra-High
Main Functions:
Flocculation, Sludge Conditioning, Dewatering And Clarification
Packaging Details:
30kgs, 50kgs, 250kgs, 1250kgs drums
Highlight:

High-Molecular-Weight CPAM Emulsion

,

CPAM Emulsion for sludge treatment

,

Polyelectrolyte Flocculant for wastewater

Product Description
Blufloc PAM Emulsion

Cationic PAM Emulsion for Chemical Industry Sludge Dewatering

High-molecular-weight CPAM emulsion for complex chemical wastewater sludge containing precipitated metals, resin fines, pigments, surfactants, reaction residues, biological solids, and inorganic coagulant sludge.

High Molecular Weight Medium to Ultra Charge Batch-Specific Screening Mechanical Dewatering

Application Snapshot

  • Product Cationic PAM Emulsion
  • Grades EC 8040, EC 8050, EC 8060, EC 8080
  • Sludge Mixed chemical and biological solids
  • Selection Representative sample and plant trial
Product Introduction

One Site Can Produce Several Different Sludges

Chemical-industry sludge is not a single material. It may include precipitated metals, resin fines, pigments, surfactants, reaction residues, biological solids, and inorganic coagulant sludge.

Because one site can produce several wastewater campaigns, the polymer program should define an operating envelope rather than rely on a single test under ideal conditions.

Blufloc CPAM Emulsion

High-molecular-weight CPAM emulsion provides bridging and charge adjustment for complex chemical wastewater sludge.

Blufloc medium- to ultra-charge grades allow application screening around pH, salts, surfactants, and upstream coagulants.

Application Challenges

Why Chemical Sludge Performance Can Change by Batch

Changes in campaign chemistry can alter surface charge, polymer adsorption, floc strength, and the final dewatering response.

01

Variable Water Chemistry

Rapid changes in pH, conductivity, and surface charge alter polymer demand.

02

Interfering Chemicals

Surfactants or solvents can interfere with adsorption and stable floc formation.

03

Mixed Solids

Inorganic precipitate and biological solids may require different charge conditions.

04

Short High-Load Events

Batch wastewater can create peak loads that differ sharply from routine operation.

Treatment Mechanism

How the PAM Emulsion Works

High-molecular-weight polymer chains bridge destabilized particles, while cationic groups help neutralize anionic surfaces.

Step 1

Adjust Surface Charge

Cationic groups adsorb onto negatively charged chemical and biological solids.

Step 2

Bridge Mixed Particles

Long polymer chains connect destabilized particles into larger, separable floc.

Step 3

Release and Separate Water

Stronger floc supports settling, drainage, thickening, or mechanical dewatering.

Important: In highly saline or chemically complex water, chain configuration and adsorption can change. The grades below are starting candidates, not a fixed prescription. Final selection and dosage require representative laboratory and plant trials.
Grade Screening

Recommended Blufloc Grades

Screen adjacent charge levels at equal active polymer mass and under the same chemical sequence, dilution-water quality, and mixing conditions.

Grade Base Molecular Weight Charge Suggested Screening Role
EC 8040 Oil-based High Medium Comparator for sludge already carrying positive coagulant residual
EC 8050 Oil-based High High Broad starting candidate for mixed chemical sludge
EC 8060 Oil-based High Very High Candidate for higher organic charge demand
EC 8080 Oil-based High Ultra Specialized screen for extreme charge demand

The cationic EC and EWC series are classified as high molecular weight, while the anionic EA and EWA grades are classified as very high molecular weight. Confirm active content, viscosity, shelf life, preparation instructions, and exact commercial limits on the current grade-specific TDS and order specification.

Product Advantages

Screening Flexibility for Complex Industrial Sludge

  • Wide charge range for complex industrial sludge
  • Strong bridging from high-molecular-weight grades
  • Liquid dosing for batch and continuous processes
  • Sample-based compatibility testing
  • Technical documentation and export support
Application Process

Build a Representative Chemical-Sludge Trial

1

Separate Major Campaigns

Test major wastewater campaigns separately instead of blending every initial sample.

2

Record the Operating Context

Record pH, conductivity, key contaminants, coagulant dose, and sludge age.

3

Screen the Charge Range

Compare adjacent grades at controlled active mass and consistent mixing energy.

4

Preserve the Chemical Sequence

Test compatibility with the actual neutralization and precipitation sequence.

5

Define Operating Rules

Create separate site rules for routine, peak, and off-spec batches.

Product Selection Guidance

Use EC 8050 as a Broad Starting Point

EC 8050 is a broad starting candidate, but EC 8040 should remain in the screen when inorganic coagulants dominate. EC 8060 or EC 8080 may help when anionic organics or biological solids raise charge demand. Final confirmation requires compatibility and machine trials.

Compare Total Operating Cost

Neat-emulsion price per kilogram can be misleading. Compare candidates on active polymer mass and the complete operating result.

  • Preparation efficiency and active dose
  • Equipment throughput
  • Cake or underflow quality
  • Downstream disposal cost
Trial Data

Operating Indicators to Record

  • Settling or drainage
  • Filtrate TSS and target contaminants
  • Cake solids
  • Dose by dry solids
  • Batch identity
Troubleshooting

Do Not Average Away Batch Differences

!

Link Polymer Performance to Campaign Chemistry

When results vary by wastewater batch, develop separate dose bands instead of relying on one averaged result.

If floc suddenly becomes weak or dispersed, check for surfactant or solvent interference, changes in pH or conductivity, and changes in the upstream coagulant program.

Supply Options

Packaging

25 kg Container
200 kg Plastic Drum
1000 kg IBC
Safe Handling

Storage and Handling

Keep the package sealed in a cool, dry, ventilated area. Protect it from direct sunlight, freezing, and excessive heat.

Follow the grade-specific TDS and SDS for shelf life, handling limits, and transport classification. Polymer spills can make floors extremely slippery and should be contained and cleaned promptly.

25+ Years Water-treatment chemical manufacturing experience
3 Plants Modern production and supply support
Manufacturer Support

Why Choose Bluwat Chemicals

  • More than 25 years of manufacturing experience supported by three modern plants
  • More than 800,000 tons delivered and exports to over 100 countries and regions
  • Factory-direct coordination for grade selection, documentation, packaging, and logistics
  • Laboratory screening with customer water or sludge samples
  • TDS, SDS, COA, and applicable certification documents for the selected grade and market

For variable chemical-industry sludge conditioning, Bluwat can screen adjacent PAM emulsion grades, review preparation and dosing conditions, and help define a plant-trial plan using agreed performance indicators.

Technical Service

Quality Control and Technical Support

Specification Confirmation

Confirm the required grade specification and order documentation before production and shipment.

Representative Sample Testing

Shortlist products under realistic pH, temperature, solids, water chemistry, and shear.

Preparation and Scale-Up

Supply clear make-down, dilution, dosing, and scale-up recommendations for the selected grade.

Plant-Trial Review

Adjust charge level, dose, addition point, or mixing conditions using recorded plant data.

Frequently Asked Questions

Chemical Industry Sludge PAM Emulsion FAQ

Can one CPAM grade treat every chemical wastewater sludge?

Sometimes one grade covers a useful range, but different production campaigns can require separate dose bands or grades.

Does high conductivity affect CPAM?

It can change polymer conformation and adsorption, so tests should use the actual wastewater and dilution water.

Should metals be precipitated before polymer addition?

Where metal removal relies on precipitation, pH and precipitant steps are normally completed before flocculation. Follow the site process design.

How is scale-up risk reduced?

Use representative samples, preserve chemical order and shear, then run a controlled plant trial with defined success metrics.

Plant-Trial Planning

Define a Polymer Operating Envelope for Each Major Wastewater Campaign

Screen adjacent Blufloc CPAM emulsion grades with representative sludge, preserve the actual neutralization and precipitation sequence, and build separate dosage rules for routine, peak, and off-spec batches.